This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The discrete I/O module provides 4 input channels, 4 relay output channels with sink or source (positive/negative) discrete logic. It is an I/O module with a relay output voltage of 24V DC, 240V AC, a current consumption of 65mA, 5mA at 5V DC via bus connector. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an Insulation between input/output and internal logic at 500V AC, input and output groups at 1500V AC, open contact at 750V AC and non-insulated between inputs/outputs. It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for inputs and outputs. It is an IP20 rated product. Its dimensions are 27.4mm (Width) x 84.6mm (Depth) x 90mm (Height). It weighs 0.120kg. This product is certified by CE, CULus and C-Tick. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Product Specifications
Main
ambient air temperature for operation -10-55 °C horizontal installation, -10-35 °C vertical installation
ambient air temperature for storage -25-70 °C
current consumption 5 mA at 5 V DC via bus connector (at state off), 0 mA at 24 V DC via bus connector (at state on), 0 mA at 24 V DC via bus connector (at state off), 25 mA at 5 V DC via bus connector (at state on)
current state 0 guaranteed <= 1 mA (input)
current state 1 guaranteed >= 2.5 mA (input)
depth 84.6 mm
discrete I/O number 8
discrete input current 7 mA for input
discrete input logic sink or source (positive/negative)
discrete input number 4 for input conforming to IEC 61131-2 Type 1
discrete input voltage 24 V
discrete input voltage type DC
discrete output current 2000 mA for relay output
discrete output logic positive or negative
discrete output number 4
discrete output type relay normally open
discrete output voltage 240 V AC for relay output, 24 V DC for relay output
electrical connection 11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs and outputs
electromagnetic emission radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230-1000 MHz conforming to EN/IEC 55011
height 90 mm
input impedance 3.4 kOhm
insulation between input and internal logic at 500 V AC, non-insulated between inputs, non-insulated between outputs, between input groups and output groups at 1500 V AC, between open contact at 750 V AC
IP degree of protection IP20 with protective cover in place
local signalling 1 LED per channel (green) for I/O state
maximum cable distance between devices unshielded cable: <30 m for regular input
maximum current per output common 7 A
mechanical durability 20000000 cycles
minimum load 10 mA at 5 V DC for relay output
mounting support top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, plate or panel with fixing kit
net weight 0.95 kg
pollution degree 2
product certifications C-Tick, cULus
product or component type discrete I/O module
range compatibility Modicon M221, Modicon M241, Modicon M251, Modicon M262
range of product Modicon TM3
relative humidity 10-95 %, without condensation (in operation), 10-95 %, without condensation (in storage)
resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
resistance to fast transients 1 kV for I/O conforming to EN/IEC 61000-4-4, 2 kV for relay output conforming to EN/IEC 61000-4-4
resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
response time 4 ms (turn-on), 4 ms (turn-off)
shock resistance 15 gn for 11 ms
standards EN/IEC 61010-2-201, EN/IEC 61131-2
storage altitude 0-3000 m
surge withstand 1 kV input common mode conforming to EN/IEC 61000-4-5, 2 kV output common mode conforming to EN/IEC 61000-4-5
vibration resistance 3.5 mm at 5-8.4 Hz on DIN rail, 3 gn at 8.4-150 Hz on DIN rail, 3.5 mm at 5-8.4 Hz on panel, 3 gn at 8.4-150 Hz on panel
voltage state 0 guaranteed 0...5 V for input
voltage state 1 guaranteed 15...28.8 V for input
width 27.4 mm
Product From Same Category
Page

Items 1-10 of 110

Set Descending Direction
Page
per page
Filter By
Now Shopping by
  1. Category PLC
Shopping Options
Price
Write Your Own Review
You're reviewing:Modicon TM3 module - 8 IO relay
Your Rating

Resources

Automation and Control Essential Catalog

Download Now

Resources

Automation and Control Essential Catalog

Download Now

WhatsApp Chat WhatsApp Chat
Copyright © 2013-present Magento, Inc. All rights reserved.